China Standard Oil Injected/Free Screw Air Compressor Work Stable and Unattended Operation with Hot selling

Your content goes here. Edit or remove this text inline or in the module Content settings. You can also style every aspect of this content in the module Design settings and even apply custom CSS to this text in the module Advanced settings.

Click Here

Product Description

0.5-80 M3/Min 6-40 Bar 5.5-400 Kw Electrical Stationary Industrial AC Power Direct Driven/Coupled Rotary Screw Air Compressors Advantages

1.CZPT Enhanced energy saving screw air compressor reached the super energy saving level
 
2.Energy Efficient Index 1(EEI 1) approved according to GB19153-2009, the energy consumption is 10%~15% lower than EEI 2.
 
3.CZPT air compressor design with 72 types of technology patent, real bigger air flow 
 
4.State-of-the-art screw element, original Germany CZPT air end, ladvanced SAP profile design, superior Sweden CZPT element bearings
 
5.CZPT air compressdor dopts world-renowned components, such as Schneider electronics from France, DENAIR filters from Germany, Danfoss pressure sensor from Denmark, etc. contribute to guarantee the compressor longer service life.
 
6.Smart touch screen design and 0 pressure drop design
 
7.Higher efficiency cooling system and electrical motor
 
8.Stainless steel pipes, reasonable inner design, ensure long service life without maintenance.

Technical Parameters Of Energy Saving Rotary Screw Air Compressor 

Model Maxinmum working Capacity(FAD)* Installed motor power Driving mode& Noise Dimensions(mm) Weight Air outlet
pressure 50 HZ 60 HZ Cooling method level** pipe diameter
bar(g) psig m3/min cfm m3/min cfm kw hp   dB(A) L W H kg  
DA-5 7.5  109 0.80  28 0.80  28 5.5 7.5 Belt Driven 75 900 600 860 315 G3/4″
8.5  123 0.78  28 0.78  28 5.5 7.5 Air Cooling 75 900 600 860
DA-7 7.5  109 1.09  39 1.09  39 7.5 10   75 900 600 860 315 G3/4″
8.5  123 1.07  38 1.07  38 7.5 10   75 900 600 860
10.5  152 0.92  32 0.91  32 7.5 10   75 900 600 860
13.0  189 0.73  26 0.72  26 7.5 10   75 900 600 860
DA-11 7.5  109 1.66  59 1.66  59 11 15   75 1230 650 900 324 G3/4″
8.5  123 1.64  58 1.64  58 11 15   75 1230 650 900
10.5  152 1.45  51 1.45  51 11 15   75 1230 650 900
13.0  189 1.13  40 1.12  40 11 15   75 1230 650 900
DA-15 7.5  109 2.54  90 2.53  89 15 20 Direct Driven 75 1465 990 1345 453 G1-1/4″
8.5  123 2.51  88 2.50  88 15 20 Air Cooling 75 1465 990 1345
10.5  152 1.97  70 1.86  66 15 20   75 1465 990 1345
13.0  189 1.91  67 1.83  65 15 20   75 1465 990 1345
DA-18 7.5  109 3.04  107 3.65  129 18.5 25   75 1465 990 1345 453 G1-1/4″
8.5  123 3.03  107 3.63  128 18.5 25   75 1465 990 1345
10.5  152 3.00  106 2.38  84 18.5 25   75 1465 990 1345
13.0  189 1.91  67 2.36  83 18.5 25   75 1465 990 1345
DA-22 7.5  109 3.57  126 3.65  129 22 30   75 1465 990 1345 477 G1-1/4″
8.5  123 3.55  125 3.63  128 22 30   75 1465 990 1345
10.5  152 3.00  106 2.38  84 22 30   75 1465 990 1345
13.0  189 2.97  105 2.36  83 22 30   75 1465 990 1345
DA-30 7.5  109 5.28  187 4.49  159 30 40   85 1600 1250 1550 682 G1-1/2″
8.5  123 5.26  186 4.48  158 30 40   85 1600 1250 1550
10.5  152 5.21  184 4.47  158 30 40   85 1600 1250 1550
13.0  189 3.45  122 3.58  126 30 40   85 1600 1250 1550
DA-37 7.5  109 6.54  231 6.33  224 37 50   85 1600 1250 1550 728 G1-1/2″
8.5  123 6.52  230 6.30  222 37 50   85 1600 1250 1550
10.5  152 5.21  184 4.47  158 37 50   85 1600 1250 1550
13.0  189 5.16  182 4.43  156 37 50   85 1600 1250 1550
DA-45 7.5  109 7.67  271 7.79  275 45 60   85 1600 1250 1550 728 G1-1/2″
8.5  123 7.62  269 7.76  574 45 60   85 1600 1250 1550
10.5  152 6.46  228 6.24  220 45 60   85 1600 1250 1550
13.0  189 6.41  226 4.44  157 45 60   85 1600 1250 1550
DA-55 7.5  109 9.76  345 9.14  323 55 75   85 1876 1326 1700 1310 G2″
8.5  123 9.67  342 9.06  320 55 75   85 1876 1326 1700
10.5  152 7.53  266 7.74  273 55 75   85 1876 1326 1700
13.0  189 7.40  261 6.30  222 55 75   85 1876 1326 1700
DA-75 7.5  109 14.21  502 11.72  414 75 100   85 1876 1326 1700 1325 G2″
8.5  123 12.55  443 11.63  411 75 100   85 1876 1326 1700
10.5  152 9.51  336 11.43  404 75 100   85 1876 1326 1700
13.0  189 9.23  326 8.75  309 75 100   85 1876 1326 1700
DA-90(W) 7.5  109 16.62  587 17.01  601 90 120 Direct Driven 72 2450 1800 1700 2450 DN80
8.5  123 16.37  578 16.82  594 90 120 Air Cooling Or 72 2450 1800 1700
10.5  152 14.21  502 14.87  525 90 120 Water Cooling 72 2450 1800 1700
13.0  189 11.77  416 11.27  398 90 120   72 2450 1800 1700
DA-110(W) 7.5  109 20.13  711 19.10  674 110 150   72 2450 1800 1700 2500 DN80
8.5  123 20.05  708 19.06  673 110 150   72 2450 1800 1700
10.5  152 16.33  576 17.01  601 110 150   72 2450 1800 1700
13.0  189 14.11  498 14.68  518 110 150   72 2450 1800 1700
DA-132(W) 7.5  109 22.85  807 24.37  861 132 175   72 2450 1800 1700 2600 DN80
8.5  123 22.73  802 24.23  856 132 175   72 2450 1800 1700
10.5  152 19.88  702 18.95  669 132 175   72 2450 1800 1700
13.0  189 16.51  583 16.82  594 132 175   72 2450 1800 1700
DA-160(W) 7.5  109 26.92  950 27.90  985 160 215   78 2650 1700 1850 3200 DN80
8.5  123 26.86  949 27.76  980 160 215   78 2650 1700 1850
10.5  152 22.44  792 23.97  846 160 215   78 2650 1700 1850
13.0  189 19.63  693 18.82  664 160 215   78 2650 1700 1850
DA-185(W) 7.5  109 28.89  1571 30.53  1078 185 250   78 2650 1700 1850 3300 DN80
8.5  123 28.84  1018 30.44  1075 185 250   78 2650 1700 1850
10.5  152 25.11  886 27.46  970 185 250   78 2650 1700 1850
13.0  189 22.08  780 23.69  836 185 250   78 2650 1700 1850
DA-200(W) 7.5  109 31.88  1126 30.53  1078 200 270   80 3000 1950 2030 4750 DN100
8.5  123 31.82  1124 30.44  1075 200 270   80 3000 1950 2030
10.5  152 28.48  1006 30.22  1067 200 270   80 3000 1950 2030
13.0  189 25.00  883 27.07  956 200 270   80 3000 1950 2030
DA-220(W) 7.5  109 36.20  1278 37.22  1314 220 300   80 3000 1950 2030 4800 DN100
8.5  123 36.15  1276 37.17  1312 220 300   80 3000 1950 2030
10.5  152 31.71  1120 33.25  1174 220 300   80 3000 1950 2030
13.0  189 28.48  1006 27.07  956 220 300   80 3000 1950 2030
DA-250(W) 7.5  109 43.31  1529 42.87  1514 250 350   80 3000 1950 2030 4850 DN100
8.5  123 43.24  1527 41.30  1458 250 350   80 3000 1950 2030
10.5  152 36.03  1272 37.04  1308 250 350   80 3000 1950 2030
13.0  189 31.55  1114 33.15  1170 250 350   80 3000 1950 2030
DA-280(W) 7.5  109 46.59  1645 47.16  1665 280 375   85 3700 2300 2450 5200 DN125
8.5  123 46.53  1643 45.64  1612 280 375   85 3700 2300 2450
10.5  152 42.95  1516 42.56  1503 280 375   85 3700 2300 2450
13.0  189 35.89  1267 36.95  1305 280 375   85 3700 2300 2450
DA-315(W) 7.5  109 53.16  1877 50.88  1797 315 425   85 3700 2300 2450 6000 DN125
8.5  123 52.63  1858 50.83  1795 315 425   85 3700 2300 2450
10.5  152 43.05  1520 46.27  1634 315 425   85 3700 2300 2450
13.0  189 42.93  1516 40.32  1424 315 425   85 3700 2300 2450
DA-355(W) 7.5  109 63.37  2238 58.12  2052 355 475   85 4500 2500 2450 7000 DN125
8.5  123 63.16  2230 56.54  1997 355 475   85 4500 2500 2450
10.5  152 52.63  1858 51.57  1821 355 475   85 4500 2500 2450
13.0  189 43.79  1546 45.35  1601 355 475   85 4500 2500 2450
DA-400(W) 7.5  109 70.99  2507 61.72  2179 400 550   85 4500 2500 2450 8000 DN125
8.5  123 70.64  2494 59.72  2109 400 550   85 4500 2500 2450
10.5  152 52.63  1858 56.52  1996 400 550   85 4500 2500 2450
13.0  189 46.34  1636 51.35  1813 400 550   85 4500 2500 2450

*) FAD in accordance with ISO 1217 : 2009, Annex C: Absolute intake pressure 1 bar (a), cooling and air intake temperature 20 °C
**) Noise level as per ISO 2151 and the basic standard ISO 9614-2, operation at maximum operating pressure and maximum speed; tolerance: ± 3 dB(A)
***) EEI 1- Energy Effiency Index 1, which refers to enhanced energy saving series
Specifications are subject to change without notice.

DENAIR Factory & Product Lines

DENAIR Exhibition

We carefully selected for you the classic case

Enhanced Energy Saving Air Compressor in Oman

Project Name: Sandblasting in Muscat, Oman.

Product Name: 75KW 100HP Enhanced Energy Saving screw air compressor EEI 1 (Energy Efficiency Index 1) with air dryer, air receiver tank and air filters.

Model No. & Qty: DA-75+ x 1.

Working Time: From June, 2016 till now

Event: In June, 2015, 1 set of CZPT enhanced energy saving air compressor system was installed in Muscat Oman. This is the first project finished by CZPT distributor in Oman. Our partner Mr. Hari shared the photos at working site to us as a good starting. That means more and more CZPT energy saving solutions will contribute to the industries in Oman in the near future. CZPT air compressor factory and air compressor distributor will try the best to provide top quality products, cost effective solution and excellent service for local users in Oman. In order to ensure the most professional service, the distributor plans to send 2 service engineers to CZPT factory in ZheJiang for training and learnin. We will update the news at that time.

FAQ

Q1: Are you factory or trade company?  
A1: We are factory.

Q2: What the exactly address of your factory? 
A2:No. 366, YangzhuangBang Street, Pingxing Rd., Xindai Town, HangZhou, ZHangZhoug Province, China

Q3: Warranty terms of your air compressor machine? 
A3: Two years warranty for the machine and technical support according to your needs.

Q4: Will you provide some spare parts of the air compressor? 
A4: Yes, of course.

Q5: How long will you take to arrange production? 
A5: 380V 50HZ we can delivery the goods within 10 days. Other electricity or other color we will delivery within 22 days

Q6: Can you accept OEM orders? 
A6: Yes, with professional design team, OEM orders are highly welcome.

How to Repair and Maintain an Air Compressor

A compressor is a device used to move air from 1 place to another. Air enters the air compressor through the intake valve. Inside the compressor, the vanes on the inner rotor rotate within an eccentric cavity. The self-adjusting length arm divides the space into multiple cavities of different sizes. As the rotor rotates, air fills the cavity. As air flows around the cavity, it builds pressure and is squeezed out of the compressor output.

Positive displacement

Positive displacement air compressors use reciprocating pistons to compress air. Gas is drawn in during the suction stroke and compressed by moving the piston in the opposite direction. It then discharges the compressed air by moving it in the opposite direction. This type of air compressor is most commonly found in automobiles, refrigerators, and other applications that require high pressure. However, it is not as efficient as a centrifugal compressor.
Most modern air compressors use positive displacement. Positive displacement models capture a volume of air in the compression chamber and distribute it when the pump is operating at maximum capacity. They are more economical than their negative displacement counterparts. Reciprocating screw air compressors are the most common positive displacement compressors. The reciprocating screw air compressor adopts a water jacket around the cylinder and is often used in processes such as oil drilling.
A bicycle pump is an example of positive displacement compression. Air is drawn into the cylinder and compressed by the moving piston. A piston compressor works on the same principle, but it uses a rotating crankshaft or connecting rod to complete the movement of the pistons. There are 2 types of positive displacement compressors: single-acting and double-acting. Both types work on the same principle, both are positive displacement compressors. The difference between the 2 types is the pressure ratio.
In air compression, positive displacement compression reduces the volume of the fluid and reduces its viscosity. This results in higher pressure ratios and is used in centrifugal, axial, and scroll compressors. Positive displacement is a common feature of most air compressors. Positive displacement compressors offer the same benefits and are more energy-efficient when applied to oil-free and gas applications. This type of compression is usually the best choice for low-pressure applications.
air-compressor

oil free

If you’re looking for an air compressor for your business, consider an oil-free air compressor. These models offer cleaner, quieter operation than traditional air compressors and require less maintenance. They also meet ISO Class 0 or Class 1 air purity requirements. Oil-free air compressors are also quieter, with fewer moving parts and less noise. These advantages make oil-free air compressors an ideal solution for many commercial applications.
Air purity is critical in many industries. Even the tiniest drop of oil can damage production equipment or damage products. The best way to find an oil-free air compressor for your business is to consider the process and end product. As air quality improves, more and more businesses are turning to oil-free compressors. Some of the advantages and disadvantages of these air compressors are:
When choosing an oil-free air compressor, it is important to understand the terminology used in the industry. Knowing these terms will make it easier for you to choose the right compressor for your needs. ACTFM, or actual cubic feet per minute, is an industry term for measuring the amount of air pumped in 1 minute under rated conditions. Although a simple number, it can be very useful in determining which type of air compressor is best for your application.
The ISO 8573-1 international standard defines air quality and provides air purity classifications. The strictest classification is air purity class 0. Many manufacturers claim that oil-free air compressors meet this standard. However, a class 0 oil-free air compressor does not necessarily mean that the air is free of contaminants. In fact, Class 0 is the benchmark for air purity. While zero air quality is the highest level, that doesn’t mean it’s completely oil-free.
air-compressor

double acting

A double-acting air compressor is a device that uses compressed air to generate electricity. Its working principle is based on piston and connecting rod. The connecting rod connects the crankshaft to the piston through pins and caps. The piston moves as the piston moves. Rods are usually made of forged carbon steel. In terms of service and maintenance, double-acting compressors require regular vise maintenance and proper cleaning.
The displacement of the compressor is a measure of the displacement that the piston can produce in a certain period of time. Displacement is usually expressed in actual cubic feet per minute. The exact calculation depends on the type of cylinder and the configuration of the compressor. Single-acting cylinders can have head-end or crank-end displacement, both of which can be measured using the displacement equation. A double-acting air compressor will use this equation. 4 and 6 calculate the displacement.
Double-acting air compressors have multiple cylinders and are made of cast iron. They are water-cooled and have a mechanical connection between the piston and connecting rod. A double-acting compressor compresses air twice per revolution of the motor. One cylinder moves up, while the other cylinder moves down. The piston moves down, allowing air to enter through valve #1. During the operation of the compressor, the temperature of the air and gas increases.
Double-acting air compressors typically have high pressure and are considered workhorses. Double-acting compressors also feature intercooling and double compression. As a result, these machines tend to last longer than single-acting compressors. Its low speed and dual compression make it a workhorse in the compressor industry. Double-acting air compressors are workhorses and versatile devices.
air-compressor

fuel tank pressure switch

You can adjust the pressure in the air compressor tank by adjusting the differential pressure. You can turn the mainspring clockwise or counterclockwise to increase or decrease the pressure. This valve will open when the pressure is low enough to start the compressor. If the pressure is too low, the valve should be closed. The cut-in and cut-out pressures should be set to appropriate values. After adjusting the tank pressure, check the hysteresis of the tank pressure switch and set the desired shutoff pressure.
If the pressure in the tank falls below the cut-in level, the tank pressure switch must be replaced. You can test the switch with a multimeter. Make sure the switch is not damaged. If you can’t find the switch, you can look at the other sections. If you find any damaged or missing parts, you should replace them. Otherwise, it may be time to check the tank pressure switch. You may need to disassemble the compressor and remove the switch.
The fuel tank pressure switch is an important part of the air compressor. It keeps you informed of the amount of air delivered by the compressor. If your tank or tank is damaged, your readings will be wrong. If the pressure switch is damaged, it will not function properly and result in incorrect readings. Fortunately, there are some easy ways to fix this. To prevent this from happening, keep the tank pressure switch in good condition.
When the air pressure in the tank drops to the cut-in pressure setting, the switch allows power to flow through it. This will start the motor and pump of the air compressor. Then, if the pressure in the tank rises above the cut-off level, the switch will trip and stop the compressor. This will prevent it from being over-pressurized. Power flow will continue to flow to the motor. Depending on your compressor model, you can change the cut-in and cut-out pressures as needed.

energy source

The power supply of the air compressor is very important. Most air compressors run on 12 VDC, which is ideal for automotive use. Alternatively, you can buy a switching power supply for around $20. No matter which power supply you choose, you must ensure that it can support the maximum current of the compressor. You can find power supplies in all sizes, from quarter-horsepower to five-horsepower.
The voltage required for a three-phase air compressor will vary. Three-phase air compressors require 3 separate power cords and a three-phase electrical service panel. This is because a standard 120/240-volt electrical service panel is not sufficient to power a three-phase compressor. Additionally, three-phase compressors require 3 separate isolated wires for the engine and motor circuits. Three-phase compressors do not require a neutral wire.

China Standard Oil Injected/Free Screw Air Compressor Work Stable and Unattended Operation     with Hot sellingChina Standard Oil Injected/Free Screw Air Compressor Work Stable and Unattended Operation     with Hot selling

Recent Posts