China Air Dryer Compressor Refrigerated for Sale for Air Compressor System with Best Sales

Your content goes here. Edit or remove this text inline or in the module Content settings. You can also style every aspect of this content in the module Design settings and even apply custom CSS to this text in the module Advanced settings.

Click Here

Item Description

Cleanse, Dry and Dependable Compressed Air

PSI specifically developed PFD refrigeration air dryer with intention of blend of trustworthiness and optimum efficiency. PFD refrigeration air dryer is made to remove h2o vapour from the compressed air by cooling by way of a very successful refrigerant circuit. PFD provides air good quality in accordance with ISO8573.1 Class 4 for drinking water vapour.

PFD has been made with conclude user in head and with simply and rapidly removable panel, person can effortless entry to the interior main refrigeration parts for maintenance and cleansing.

All versions comply with the requirement of electromagnetic compatibility directive 2004/108/EC, low voltage directive 2006/ninety five/EC as effectively as with the machinery directive 2006/forty two/EC.

Functions of PSI Refrigerated Air Dryer 
PSI Refrigerated Air Dryer Approach Details

Model Air Connection Power Provide Nominal flow rate Dimensions (mm) Weight (kg)
cfm mthree/h L W H
PFD36 Rc 1/2″ 230V/1Ph/50Hz 21 36 500 250 five hundred twenty five
PFD54 Rc 1/2″ 230V/1Ph/50Hz 32 54 five hundred 250 five hundred 25
PFD72 Rc 1/2″ 230V/1Ph/50Hz 42 seventy two 600 310 five hundred 30
PFD90 Rc 1/2″ 230V/1Ph/50Hz fifty three 90 600 310 five hundred 30
PFD108 Rc 1/2″ 230V/1Ph/50Hz sixty four 108 600 310 five hundred thirty
PFD144 Rc 3/4″ 230V/1Ph/50Hz eighty five 144 750 360 550 fifty
PFD180 Rc 3/4″ 230V/1Ph/50Hz 106 a hundred and eighty 750 360 550 50
PFD216 Rc 3/4″ 230V/1Ph/50Hz 127 216 750 360 550 55
PFD240 Rc 3/4″ 230V/1Ph/50Hz 142 240 750 360 550 55
PFD330A Rc 1 1/2′ 400V/3Ph/50Hz 195 330 750 592 913 seventy three
PFD390A Rc 1 1/2′ 400V/3Ph/50Hz 229 390 750 592 913 seventy eight
PFD510A Rc 1 1/2′ 400V/3Ph/50Hz three hundred 510 750 592 913 80
PFD600A Rc 1 1/2′ 400V/3Ph/50Hz 353 600 750 592 913 eighty five
PFD720A Rc 2″ 400V/3Ph/50Hz 424 seven-hundred a thousand 710 1030 a hundred thirty
PFD900A Rc 2″ 400V/3Ph/50Hz 530 900 one thousand 710 1030 a hundred and forty
PFD1200A Rc 2″ 400V/3Ph/50Hz 706 1200 one thousand 710 1030 one hundred fifty
PFD1500A Rc 2 1/2″ 400V/3Ph/50Hz 883 1500 a thousand 820 1600 250
PFD1800A Rc 2 1/2″ 400V/3Ph/50Hz 1059 1800 a thousand 820 1600 260
PFD2100A Rc 2 1/2″ 400V/3Ph/50Hz 1236 2100 a thousand 820 1600 270
PFD2400A DN100 400V/3Ph/50Hz 1412 2400 1250 1120 1750 500
PFD3000A DN100 400V/3Ph/50Hz 1765 3000 1250 1120 1750 510
PFD3600A DN100 400V/3Ph/50Hz 2118 3600 1250 1120 1750 550
PFD4200A DN125 400V/3Ph/50Hz 2471 4200 1250 1120 1750 580
PFD4800A DN150 400V/3Ph/50Hz 2824 4800 2000 1515 1770 700
PFD5400A DN150 400V/3Ph/50Hz 3177 5400 2000 1515 1770 720
PFD6000A DN150 400V/3Ph/50Hz 3530 6000 2000 1515 1770 940
PFD7200A DN150 400V/3Ph/50Hz 4236 7200 2000 1515 1770 950
PFD9000W DN200 400V/3Ph/50Hz 5295 9000 2135 1225 1800 1150
PFD10800W DN200 400V/3Ph/50Hz 6354 10800 2135 1225 1800 1350

Nominal dryer flow rated at inlet strain 7 barg, inlet air temperature 42ºC, ambient temperature 38ºC and dew stage 3ºC to 10ºC.

H2o cooled alternative is accessible from PFD720 and above.

PSI Refrigerated Air Dryer Packing
Other PSI Sizzling Sale Merchandise

The software of PSI refrigeration air dryer

About PSI Filtration 
PSI Manufacturing unit
Shipping and delivery of Compressed Air Dryer

 

After-sales Service: on Line Service
Warranty: One Year
Flow: Cross Flow
Operation Pressure: 0.6–40MPa
Inlet Temperature: 38°c
Cooling Way: Air Cooling

###

Customization:

###

Model Air Connection Power Supply Nominal flow rate Dimensions (mm) Weight (kg)
cfm m3/h L W H
PFD36 Rc 1/2" 230V/1Ph/50Hz 21 36 500 250 500 25
PFD54 Rc 1/2" 230V/1Ph/50Hz 32 54 500 250 500 25
PFD72 Rc 1/2" 230V/1Ph/50Hz 42 72 600 310 500 30
PFD90 Rc 1/2" 230V/1Ph/50Hz 53 90 600 310 500 30
PFD108 Rc 1/2" 230V/1Ph/50Hz 64 108 600 310 500 30
PFD144 Rc 3/4" 230V/1Ph/50Hz 85 144 750 360 550 50
PFD180 Rc 3/4" 230V/1Ph/50Hz 106 180 750 360 550 50
PFD216 Rc 3/4" 230V/1Ph/50Hz 127 216 750 360 550 55
PFD240 Rc 3/4" 230V/1Ph/50Hz 142 240 750 360 550 55
PFD330A Rc 1 1/2′ 400V/3Ph/50Hz 195 330 750 592 913 73
PFD390A Rc 1 1/2′ 400V/3Ph/50Hz 229 390 750 592 913 78
PFD510A Rc 1 1/2′ 400V/3Ph/50Hz 300 510 750 592 913 80
PFD600A Rc 1 1/2′ 400V/3Ph/50Hz 353 600 750 592 913 85
PFD720A Rc 2" 400V/3Ph/50Hz 424 700 1000 710 1030 130
PFD900A Rc 2" 400V/3Ph/50Hz 530 900 1000 710 1030 140
PFD1200A Rc 2" 400V/3Ph/50Hz 706 1200 1000 710 1030 150
PFD1500A Rc 2 1/2" 400V/3Ph/50Hz 883 1500 1000 820 1600 250
PFD1800A Rc 2 1/2" 400V/3Ph/50Hz 1059 1800 1000 820 1600 260
PFD2100A Rc 2 1/2" 400V/3Ph/50Hz 1236 2100 1000 820 1600 270
PFD2400A DN100 400V/3Ph/50Hz 1412 2400 1250 1120 1750 500
PFD3000A DN100 400V/3Ph/50Hz 1765 3000 1250 1120 1750 510
PFD3600A DN100 400V/3Ph/50Hz 2118 3600 1250 1120 1750 550
PFD4200A DN125 400V/3Ph/50Hz 2471 4200 1250 1120 1750 580
PFD4800A DN150 400V/3Ph/50Hz 2824 4800 2000 1515 1770 700
PFD5400A DN150 400V/3Ph/50Hz 3177 5400 2000 1515 1770 720
PFD6000A DN150 400V/3Ph/50Hz 3530 6000 2000 1515 1770 940
PFD7200A DN150 400V/3Ph/50Hz 4236 7200 2000 1515 1770 950
PFD9000W DN200 400V/3Ph/50Hz 5295 9000 2135 1225 1800 1150
PFD10800W DN200 400V/3Ph/50Hz 6354 10800 2135 1225 1800 1350
After-sales Service: on Line Service
Warranty: One Year
Flow: Cross Flow
Operation Pressure: 0.6–40MPa
Inlet Temperature: 38°c
Cooling Way: Air Cooling

###

Customization:

###

Model Air Connection Power Supply Nominal flow rate Dimensions (mm) Weight (kg)
cfm m3/h L W H
PFD36 Rc 1/2" 230V/1Ph/50Hz 21 36 500 250 500 25
PFD54 Rc 1/2" 230V/1Ph/50Hz 32 54 500 250 500 25
PFD72 Rc 1/2" 230V/1Ph/50Hz 42 72 600 310 500 30
PFD90 Rc 1/2" 230V/1Ph/50Hz 53 90 600 310 500 30
PFD108 Rc 1/2" 230V/1Ph/50Hz 64 108 600 310 500 30
PFD144 Rc 3/4" 230V/1Ph/50Hz 85 144 750 360 550 50
PFD180 Rc 3/4" 230V/1Ph/50Hz 106 180 750 360 550 50
PFD216 Rc 3/4" 230V/1Ph/50Hz 127 216 750 360 550 55
PFD240 Rc 3/4" 230V/1Ph/50Hz 142 240 750 360 550 55
PFD330A Rc 1 1/2′ 400V/3Ph/50Hz 195 330 750 592 913 73
PFD390A Rc 1 1/2′ 400V/3Ph/50Hz 229 390 750 592 913 78
PFD510A Rc 1 1/2′ 400V/3Ph/50Hz 300 510 750 592 913 80
PFD600A Rc 1 1/2′ 400V/3Ph/50Hz 353 600 750 592 913 85
PFD720A Rc 2" 400V/3Ph/50Hz 424 700 1000 710 1030 130
PFD900A Rc 2" 400V/3Ph/50Hz 530 900 1000 710 1030 140
PFD1200A Rc 2" 400V/3Ph/50Hz 706 1200 1000 710 1030 150
PFD1500A Rc 2 1/2" 400V/3Ph/50Hz 883 1500 1000 820 1600 250
PFD1800A Rc 2 1/2" 400V/3Ph/50Hz 1059 1800 1000 820 1600 260
PFD2100A Rc 2 1/2" 400V/3Ph/50Hz 1236 2100 1000 820 1600 270
PFD2400A DN100 400V/3Ph/50Hz 1412 2400 1250 1120 1750 500
PFD3000A DN100 400V/3Ph/50Hz 1765 3000 1250 1120 1750 510
PFD3600A DN100 400V/3Ph/50Hz 2118 3600 1250 1120 1750 550
PFD4200A DN125 400V/3Ph/50Hz 2471 4200 1250 1120 1750 580
PFD4800A DN150 400V/3Ph/50Hz 2824 4800 2000 1515 1770 700
PFD5400A DN150 400V/3Ph/50Hz 3177 5400 2000 1515 1770 720
PFD6000A DN150 400V/3Ph/50Hz 3530 6000 2000 1515 1770 940
PFD7200A DN150 400V/3Ph/50Hz 4236 7200 2000 1515 1770 950
PFD9000W DN200 400V/3Ph/50Hz 5295 9000 2135 1225 1800 1150
PFD10800W DN200 400V/3Ph/50Hz 6354 10800 2135 1225 1800 1350

Choosing the Right Air Compressor For Your Home

You will find that air compressors are indispensable tools for a variety of situations, including garages, home workshops, and basements. These tools can power a variety of tools, and each model is sized to suit the job at hand. Because air compressors have only one motor, they are lightweight, compact, and easy to handle. Using one air compressor to power several tools will also reduce the wear and tear on individual components. This article will introduce some important characteristics to look for when choosing the right air compressor for your home.

Positive displacement

A positive displacement compressor applies pressure to a fluid, whereas a centrifugal one does the opposite. A positive displacement compressor creates the desired pressure by trapping air and increasing its volume. Its discharge valve releases the high-pressure gas. These compressors are used in industrial applications and nuclear power plants. The difference between a positive and negative displacement compressor is that a positive displacement compressor can compress and release air at a consistent rate.
A positive displacement air compressor uses a reciprocating piston to compress air. This reduces the volume of the air in the compression chamber, and a discharge valve opens when the pressure reaches the desired level. These compressors are used in bicycle pumps and other pneumatic tools. Positive displacement air compressors have multiple inlet ports and have several configurations. Positive displacement air compressors have a single-acting and double-acting piston, and can be oil-lubricated or oil-free.
A positive displacement air compressor is different from a dynamic compressor. It draws air into the compression chambers and then releases the pressure when the valve is opened. Positive displacement compressors are common in industrial applications and are available in single-acting, double-acting, and oil-lubricated models. Large piston compressors have ventilated intermediate pieces and crossheads on gudgeon pins. Smaller models have permanently sealed crankcases with bearings.
air-compressor

Oil-free

Oil-free air compressors have some advantages over their oil-lubricated counterparts. They do not require lubrication oil because they are coated with Teflon. The material has one of the lowest coefficients of friction and is layered, so it slides past other layers with little effort. Because of this, oil-free compressors tend to be cheaper and still deliver comparable performance. Oil-free compressors are a good choice for industrial applications.
The life of an oil-free air compressor is significantly longer than an oil-lubricated counterpart. These models can operate up to 2,000 hours, four times longer than the average oil-lubed compressor. Oil-free compressors also have a significantly lower operating noise than their oil-lubricated counterparts. And because they don’t need oil changes, they are quieter. Some even last up to 2,000 hours.
An oil-free air compressor is a good choice if your application requires high levels of purity. Several applications require ultra-pure air, and even a drop of oil can cause product spoilage or damage to production equipment. In addition to the health risks, an oil-free air compressor reduces the costs associated with oil contamination and minimizes leaks. It also eliminates the need for oil collection, disposal, and treatment.
A typical oil-free air compressor is very efficient, requiring only about 18% of the full load horsepower. However, oil-free compressors have a higher risk of premature failure and are not recommended for large-scale industrial applications. They may also use up to 18% of the compressor’s full capacity. They may sound appealing, but you must make sure you understand the benefits of an oil-free air compressor before choosing one for your industrial applications.

Single-stage

A single-stage air compressor is designed to provide the power for a single pneumatic tool or device. These machines are generally smaller than two-stage compressors and produce less heat and energy. These machines aren’t designed for heavy-duty industries, but they are still highly effective for a variety of applications, including auto shops, gas stations, and various manufacturing plants. They can also be used in borewells, as they are suitable for small spaces with low air flow requirements.
A single-stage air compressor has one cylinder and two valves – the inlet and the delivery valves. Both of these valves function mechanically, with the inlet valve controlling torque and the delivery one controlling air pressure. Generally, single-stage compressors are powered by a gas engine, but there are also electric models available. The single-stage air compressor is the most common type of air compressor. It has a single cylinder, one piston, and one air cylinder.
The single-stage air compressors are used for small projects or personal use. A two-stage air compressor is more effective for industrial projects. Its longer air end life makes it more efficient. It is also more efficient for use in the automotive industry, where the engine has many cylinders. In general, single-stage compressors require a higher power level. The single-stage model is ideal for small projects, while a two-stage one is suitable for larger-scale arsenals.
air-compressor

CFM

The cubic foot-per-minute (CFM) of an air compressor is the output of the machine. In order to calculate the CFM level, start by looking at the compressor’s specifications. You should know how many cubic feet the unit can hold and how many pounds per square inch it can compress. Once you have these information, you can calculate the CFM. Now you can use these numbers to select an appropriate air compressor for your needs.
The most common way to increase the CFM of an air compressor is to turn the regulator down. By turning the dial down, the air compressor will produce more than 10 CFM. You can also try connecting two output valves. Make sure that the settings are adjusted properly before you begin. This will ensure that your air compressor is functioning at its maximum efficiency and lifespan. To increase the CFM of your air compressor, first check that your regulator is calibrated for the desired pressure level.
To calculate the CFM of an air compressor, first determine the tank volume of the machine. Then, multiply this volume by the time it takes to fill the tank. Then, divide the result by 60 seconds to calculate the CFM. Once you know how much air your machine can hold, you can choose a suitable air compressor. If you’re working in a confined area, you should buy a tool with a large tank.

PSI

The PSI of an air compressor is the pressure that it can output. A typical air compressor has a gauge connected to the airline at the bottom, next to it, or between the two. The gauge tells the actual pressure of the air compressor, while the cut-out pressure is determined by the manufacturer. The manufacturer recommends that you set the cut-out pressure twenty to forty PSI higher than the factory recommended pressure. If you want to set the pressure for your nail gun, you can use the cut-in and cut-out pressures on your compressor, and the tank won’t exceed this range.
The PSI of an air compressor measures the force that it can deliver, which is often in pounds per square inch. For most air tools, you need at least forty to 90 psi. In general, reciprocating air compressors work on an on/off basis. This relationship is known as the duty cycle. All air compressors are rated for a particular duty cycle, such as fifty percent on and twenty-five percent off.
The Psig of an air compressor is not free, as many people believe. The PSI of an air compressor is not free, but it is essential to maintain it for safe operations. If you’re having trouble maintaining a consistent pressure, consider turning down the PSI of your compressor by 2 psig. This will determine the critical pressure for the machine. You’ll also increase the amount of energy in the system by one percent.
air-compressor

Power source

The power source for an air compressor is crucial in its operation. Without the correct voltage and amperage, air compressors will not function properly. The power source must be close to the compressor so that it can plug into an electrical outlet. If it is too far from the outlet, the compressor may not be able to build enough pressure. When this happens, the fuse inside the air compressor will turn off to protect the user. The power source should be a safe distance from the compressor.
Most manufacturers do not specify the power source for an air compressor. Depending on the horsepower, the compressor will require approximately four amps of power. A one-horsepower compressor would draw about twelve amps. If it were powered by a typical 120-volt household supply, its motor would exceed the 15-amp breaker capacity. A larger air compressor, however, will require a separate 15-amp power source, making it impossible to use it with this type of power source.
The power source for an air compressor is typically electrical alternating current (AC) that is equivalent to the voltage on a standard wall outlet. A three-phase air compressor, on the other hand, requires a special AC supply with three electrical offset pulses. Regardless of the type of air compressor, the power source must be compatible with the incoming power service. One of the most common problems when attempting to connect an air compressor to an AC power source is undersized wire. This results in low voltage and high amperes, tripping of over-load relays and blown fuses.

China Air Dryer Compressor Refrigerated for Sale for Air Compressor System     with Best SalesChina Air Dryer Compressor Refrigerated for Sale for Air Compressor System     with Best Sales
editor by czh 2023-01-21

Recent Posts