15KW strength conserving 35% (EVA) Non-inductive PM VSD screw air compressor

Technical Parameters Of PM Variable pace screw air compressor:
 

Design WZS-20EVA
Air Circulation/Operating stress two.2m3/min @ 8bar
1.8m3/min @ 10bar
Cooling sort of COMPRESSOR Air cooling
Cooling sort of MOTOR Air cooling
Driven strategy Immediate Driven
Begin way Delicate VSD Commence
VSD inverter HOLIP / VEICHI
Exhaust Temp. < ambient temp. +8 degrees
Oil articles <2ppm
Sound 66±2 dB(A)
Power 380VAC/3ph/~200Hz
Motor power 15kw/20hp
Dimension 1300*800*1030mm
Bodyweight 480kg

 

Model Power
(KW)
Pressure
(Bar)
Air flow
(m³/min)
Noise
dB(A)
Compression stages Outlet diameter
(Inch)
Dimension
(mm)
Weight
(kg)
L W H
WZS-15EVA 11 8 1.eight 62±2 Single 1″ 1300 860 1030 380
10 one.six
WZS-20EVA 15 eight two.two 63±2 Single 1″ 1300 860 1030 480
ten two.
WZS-30EVA 22 8 3.8 66±2 Single 1¼” 1380 850 1150 620
10 3.
WZS-40EVA 30 8 5. 68±2 Single 1¾” 1380 850 1150 680
ten four.four
WZS-50EVA 37 eight 6.eight 68±2 Single 1½” 1600 1000 1370 850
ten 5.4
WZS-60EVA 45 eight eight. 68±2 Single 1½” 1600 1000 1370 880
10 6.eight
WZS-75EVA 55 eight 9.7 69±2 Single 2″ 1700 1270 1500 1350
ten eight.6
WZS-100EVA 75 eight 13.2 70±2 Single 2″ 2150 1300 1700 1650
10 11.6
WZS-125EVA 90 eight fifteen. 70±2 Single 2″ 2150 1100 1500 1950
ten 14.six
WZS-150EVA 110 8 19. 71±2 Single DN65 2550 1650 1850 2600
ten 17.
WZS-180EVA 132 eight 23. 72±2 Single DN65 2550 1650 1850 2880
10 20.
WZS-200EVA 160 8 26.five 75±2 Single DN80 2950 1800 1850 3200
ten 22.5

 

Ahead of quotation:
one.Before quoting, what ought to consumers offer?
1).Discharge strain (Bar, Mpa or Psi)
two).Air discharge/Air stream/Air ability (m3/min or CFM)
three).Electricity supply (220/380V, 50/60Hz, 3Phase)

two.If I don’t know the force and air stream, what should I do?
one).Take the picture of nameplate, we will recommend the ideal air compressor to you.
2).Explain to us what industry you are, we can recommend the suited 1 (so as to air tank / air dryer / air filters).
 

Substantial Efficiency PM Motor and Energy Saving
*With the substantial-functionality long term magnet material, PM motor is not going to drop magnetism even below 120°c and can run for far more than fifteen years.
*No motor bearing: long term magnet rotors is mounted directly on the stretch out shaft of Male rotor. This composition isn’t going to have the bearing and gets rid of the motor bearing fault. 
*Comparing to normal variable speed motor, the permanent magnet synchronous motor performs with even far better energy performance. Especially in the lower-velocity problem, it can nonetheless maintain a large motor performance.

Shipping and delivery
Shipping and delivery: time 5-25 operating days following payment receipt verified(based mostly on genuine amount)
packing:normal export packing. or custom-made packing as your
Professional: items delivery forwarder.

FAQ
Q: OEM/ODM, or buyers emblem printed is offered?
Yes, OEM/ODM, clients emblem is welcomed.

Q:  Delivery day?
Generally 5-25 workdays right after getting deposit, certain supply date dependent on get amount

Q: what is actually your payment conditions?
Frequently carrying out 30% deposit and 70% equilibrium by T/T, Western Union, Paypal, otherpayment terms also can be reviewed dependent on our cooperation.

Q: How to handle your quality?
We have professional QC crew, control the top quality for the duration of the mass production and inspectthe entirely items before delivery.

Q:  If we don’t have transport forwarder in China, would you do this for us?
We can offer you very best shipping line to make sure you can get the merchandise well timed at very best price tag.

Q: arrive to China prior to, can you be my guide in China?
We are pleased to offer you orservice, these kinds of as booking ticket, choose up at the airport, booking resort, accompany going to market or manufacturing unit

Thank you extremely a lot for viewing this page, and would like you a nice day!

Contacts:Vicky Liu
Mob: -173-1655-1856
Web: compressor

 


/ Piece
|
1 Piece

(Min. Order)

###

Lubrication Style: Oil-less
Cooling System: Air Cooling
Power Source: AC Power
Cylinder Position: Vertical
Structure Type: Closed Type
Installation Type: Stationary Type

###

Customization:
Available

|


###

Model WZS-20EVA
Air Flow/Working pressure 2.2m3/min @ 8bar
1.8m3/min @ 10bar
Cooling type of COMPRESSOR Air cooling
Cooling type of MOTOR Air cooling
Driven method Direct Driven
Start way Soft VSD Start
VSD inverter HOLIP / VEICHI
Exhaust Temp. < ambient temp. +8 degrees
Oil content <2ppm
Noise 66±2 dB(A)
Power 380VAC/3ph/0~200Hz
Motor power 15kw/20hp
Dimension 1300*800*1030mm
Weight 480kg

###

Model Power
(KW)
Pressure
(Bar)
Air flow
(m³/min)
Noise
dB(A)
Compression stages Outlet diameter
(Inch)
Dimension
(mm)
Weight
(kg)
L W H
WZS-15EVA 11 8 1.8 62±2 Single 1" 1300 860 1030 380
10 1.6
WZS-20EVA 15 8 2.2 63±2 Single 1" 1300 860 1030 480
10 2.0
WZS-30EVA 22 8 3.8 66±2 Single 1¼" 1380 850 1150 620
10 3.0
WZS-40EVA 30 8 5.0 68±2 Single 1¾" 1380 850 1150 680
10 4.4
WZS-50EVA 37 8 6.8 68±2 Single 1½" 1600 1000 1370 850
10 5.4
WZS-60EVA 45 8 8.0 68±2 Single 1½" 1600 1000 1370 880
10 6.8
WZS-75EVA 55 8 9.7 69±2 Single 2" 1700 1270 1500 1350
10 8.6
WZS-100EVA 75 8 13.2 70±2 Single 2" 2150 1300 1700 1650
10 11.6
WZS-125EVA 90 8 15.0 70±2 Single 2" 2150 1100 1500 1950
10 14.6
WZS-150EVA 110 8 19.0 71±2 Single DN65 2550 1650 1850 2600
10 17.0
WZS-180EVA 132 8 23.0 72±2 Single DN65 2550 1650 1850 2880
10 20.0
WZS-200EVA 160 8 26.5 75±2 Single DN80 2950 1800 1850 3200
10 22.5

/ Piece
|
1 Piece

(Min. Order)

###

Lubrication Style: Oil-less
Cooling System: Air Cooling
Power Source: AC Power
Cylinder Position: Vertical
Structure Type: Closed Type
Installation Type: Stationary Type

###

Customization:
Available

|


###

Model WZS-20EVA
Air Flow/Working pressure 2.2m3/min @ 8bar
1.8m3/min @ 10bar
Cooling type of COMPRESSOR Air cooling
Cooling type of MOTOR Air cooling
Driven method Direct Driven
Start way Soft VSD Start
VSD inverter HOLIP / VEICHI
Exhaust Temp. < ambient temp. +8 degrees
Oil content <2ppm
Noise 66±2 dB(A)
Power 380VAC/3ph/0~200Hz
Motor power 15kw/20hp
Dimension 1300*800*1030mm
Weight 480kg

###

Model Power
(KW)
Pressure
(Bar)
Air flow
(m³/min)
Noise
dB(A)
Compression stages Outlet diameter
(Inch)
Dimension
(mm)
Weight
(kg)
L W H
WZS-15EVA 11 8 1.8 62±2 Single 1" 1300 860 1030 380
10 1.6
WZS-20EVA 15 8 2.2 63±2 Single 1" 1300 860 1030 480
10 2.0
WZS-30EVA 22 8 3.8 66±2 Single 1¼" 1380 850 1150 620
10 3.0
WZS-40EVA 30 8 5.0 68±2 Single 1¾" 1380 850 1150 680
10 4.4
WZS-50EVA 37 8 6.8 68±2 Single 1½" 1600 1000 1370 850
10 5.4
WZS-60EVA 45 8 8.0 68±2 Single 1½" 1600 1000 1370 880
10 6.8
WZS-75EVA 55 8 9.7 69±2 Single 2" 1700 1270 1500 1350
10 8.6
WZS-100EVA 75 8 13.2 70±2 Single 2" 2150 1300 1700 1650
10 11.6
WZS-125EVA 90 8 15.0 70±2 Single 2" 2150 1100 1500 1950
10 14.6
WZS-150EVA 110 8 19.0 71±2 Single DN65 2550 1650 1850 2600
10 17.0
WZS-180EVA 132 8 23.0 72±2 Single DN65 2550 1650 1850 2880
10 20.0
WZS-200EVA 160 8 26.5 75±2 Single DN80 2950 1800 1850 3200
10 22.5

Choosing the Right Air Compressor For Your Home

You will find that air compressors are indispensable tools for a variety of situations, including garages, home workshops, and basements. These tools can power a variety of tools, and each model is sized to suit the job at hand. Because air compressors have only one motor, they are lightweight, compact, and easy to handle. Using one air compressor to power several tools will also reduce the wear and tear on individual components. This article will introduce some important characteristics to look for when choosing the right air compressor for your home.

Positive displacement

A positive displacement compressor applies pressure to a fluid, whereas a centrifugal one does the opposite. A positive displacement compressor creates the desired pressure by trapping air and increasing its volume. Its discharge valve releases the high-pressure gas. These compressors are used in industrial applications and nuclear power plants. The difference between a positive and negative displacement compressor is that a positive displacement compressor can compress and release air at a consistent rate.
A positive displacement air compressor uses a reciprocating piston to compress air. This reduces the volume of the air in the compression chamber, and a discharge valve opens when the pressure reaches the desired level. These compressors are used in bicycle pumps and other pneumatic tools. Positive displacement air compressors have multiple inlet ports and have several configurations. Positive displacement air compressors have a single-acting and double-acting piston, and can be oil-lubricated or oil-free.
A positive displacement air compressor is different from a dynamic compressor. It draws air into the compression chambers and then releases the pressure when the valve is opened. Positive displacement compressors are common in industrial applications and are available in single-acting, double-acting, and oil-lubricated models. Large piston compressors have ventilated intermediate pieces and crossheads on gudgeon pins. Smaller models have permanently sealed crankcases with bearings.
air-compressor

Oil-free

Oil-free air compressors have some advantages over their oil-lubricated counterparts. They do not require lubrication oil because they are coated with Teflon. The material has one of the lowest coefficients of friction and is layered, so it slides past other layers with little effort. Because of this, oil-free compressors tend to be cheaper and still deliver comparable performance. Oil-free compressors are a good choice for industrial applications.
The life of an oil-free air compressor is significantly longer than an oil-lubricated counterpart. These models can operate up to 2,000 hours, four times longer than the average oil-lubed compressor. Oil-free compressors also have a significantly lower operating noise than their oil-lubricated counterparts. And because they don’t need oil changes, they are quieter. Some even last up to 2,000 hours.
An oil-free air compressor is a good choice if your application requires high levels of purity. Several applications require ultra-pure air, and even a drop of oil can cause product spoilage or damage to production equipment. In addition to the health risks, an oil-free air compressor reduces the costs associated with oil contamination and minimizes leaks. It also eliminates the need for oil collection, disposal, and treatment.
A typical oil-free air compressor is very efficient, requiring only about 18% of the full load horsepower. However, oil-free compressors have a higher risk of premature failure and are not recommended for large-scale industrial applications. They may also use up to 18% of the compressor’s full capacity. They may sound appealing, but you must make sure you understand the benefits of an oil-free air compressor before choosing one for your industrial applications.

Single-stage

A single-stage air compressor is designed to provide the power for a single pneumatic tool or device. These machines are generally smaller than two-stage compressors and produce less heat and energy. These machines aren’t designed for heavy-duty industries, but they are still highly effective for a variety of applications, including auto shops, gas stations, and various manufacturing plants. They can also be used in borewells, as they are suitable for small spaces with low air flow requirements.
A single-stage air compressor has one cylinder and two valves – the inlet and the delivery valves. Both of these valves function mechanically, with the inlet valve controlling torque and the delivery one controlling air pressure. Generally, single-stage compressors are powered by a gas engine, but there are also electric models available. The single-stage air compressor is the most common type of air compressor. It has a single cylinder, one piston, and one air cylinder.
The single-stage air compressors are used for small projects or personal use. A two-stage air compressor is more effective for industrial projects. Its longer air end life makes it more efficient. It is also more efficient for use in the automotive industry, where the engine has many cylinders. In general, single-stage compressors require a higher power level. The single-stage model is ideal for small projects, while a two-stage one is suitable for larger-scale arsenals.
air-compressor

CFM

The cubic foot-per-minute (CFM) of an air compressor is the output of the machine. In order to calculate the CFM level, start by looking at the compressor’s specifications. You should know how many cubic feet the unit can hold and how many pounds per square inch it can compress. Once you have these information, you can calculate the CFM. Now you can use these numbers to select an appropriate air compressor for your needs.
The most common way to increase the CFM of an air compressor is to turn the regulator down. By turning the dial down, the air compressor will produce more than 10 CFM. You can also try connecting two output valves. Make sure that the settings are adjusted properly before you begin. This will ensure that your air compressor is functioning at its maximum efficiency and lifespan. To increase the CFM of your air compressor, first check that your regulator is calibrated for the desired pressure level.
To calculate the CFM of an air compressor, first determine the tank volume of the machine. Then, multiply this volume by the time it takes to fill the tank. Then, divide the result by 60 seconds to calculate the CFM. Once you know how much air your machine can hold, you can choose a suitable air compressor. If you’re working in a confined area, you should buy a tool with a large tank.

PSI

The PSI of an air compressor is the pressure that it can output. A typical air compressor has a gauge connected to the airline at the bottom, next to it, or between the two. The gauge tells the actual pressure of the air compressor, while the cut-out pressure is determined by the manufacturer. The manufacturer recommends that you set the cut-out pressure twenty to forty PSI higher than the factory recommended pressure. If you want to set the pressure for your nail gun, you can use the cut-in and cut-out pressures on your compressor, and the tank won’t exceed this range.
The PSI of an air compressor measures the force that it can deliver, which is often in pounds per square inch. For most air tools, you need at least forty to 90 psi. In general, reciprocating air compressors work on an on/off basis. This relationship is known as the duty cycle. All air compressors are rated for a particular duty cycle, such as fifty percent on and twenty-five percent off.
The Psig of an air compressor is not free, as many people believe. The PSI of an air compressor is not free, but it is essential to maintain it for safe operations. If you’re having trouble maintaining a consistent pressure, consider turning down the PSI of your compressor by 2 psig. This will determine the critical pressure for the machine. You’ll also increase the amount of energy in the system by one percent.
air-compressor

Power source

The power source for an air compressor is crucial in its operation. Without the correct voltage and amperage, air compressors will not function properly. The power source must be close to the compressor so that it can plug into an electrical outlet. If it is too far from the outlet, the compressor may not be able to build enough pressure. When this happens, the fuse inside the air compressor will turn off to protect the user. The power source should be a safe distance from the compressor.
Most manufacturers do not specify the power source for an air compressor. Depending on the horsepower, the compressor will require approximately four amps of power. A one-horsepower compressor would draw about twelve amps. If it were powered by a typical 120-volt household supply, its motor would exceed the 15-amp breaker capacity. A larger air compressor, however, will require a separate 15-amp power source, making it impossible to use it with this type of power source.
The power source for an air compressor is typically electrical alternating current (AC) that is equivalent to the voltage on a standard wall outlet. A three-phase air compressor, on the other hand, requires a special AC supply with three electrical offset pulses. Regardless of the type of air compressor, the power source must be compatible with the incoming power service. One of the most common problems when attempting to connect an air compressor to an AC power source is undersized wire. This results in low voltage and high amperes, tripping of over-load relays and blown fuses.

China 15kw Energy Saving 35% (EVA) Non-Inductive Pm VSD Screw Air Compressor     with Great qualityChina 15kw Energy Saving 35% (EVA) Non-Inductive Pm VSD Screw Air Compressor     with Great quality
editor by CX 2023-04-03

Recent Posts